DS1602
5 of 8
Table 1. VALID PROTOCOLS
PROTOCOL
ACTION
ACC AVC OSC2 OSC1 OSC0 CCC CVC
RD
FUNCTION
Read
Continuous
Counter
1 0 X X X X X 1
Output continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Write
Continuous
Counter
1 0 X X X X X 0
Input data to continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Read V
CC
Active
Counter
0 1 X X X X X 1
Output V
CC
active
counter on the 32 clocks
following protocol,
oscillator trim register
is not updated. Counters
are not reset.
Write V
CC
Active
Counter
0 1 X X X X X 0
Input data to continuous
counter on the 32 clocks
following protocol.
Oscillator trim register
is not updated. Counters
are not reset.
Clear
Continuous
Counter
0 0 X X X 1 X X
Resets the continuous
counter to all zeros at
the end of protocol.
Oscillator trim register
is not updated.
Clear V
CC
Active
Counter
0 0 X X X X 1 X
Resets the V
CC
active
counter to all zeros at
the end of protocol.
Oscillator trim register
is not updated.
Set Oscillator
Trim Bits
1 1 A B C X X 0
Sets the oscillator trim
register to a value of
ABC. Counters are
unaffected.
X = Don’t Care