O utp ut E nab l e. O E/INT contr ol s the i np ut or outp ut status of D AT_V P /S E 0_V M and D + /D - . When
O E/INT i s l og i c 0, the d evi ce i s i n tr ansm i t m od e. W hen O E/INT i s l og i c 1, the d evi ce i s i n
r ecei ve m od e. W hen i n susp end m od e, O E/INT can b e p r og r am m ed to functi on as an i nter r up t
outp ut that d etects the sam e i nter r up ts as INT. The oe_i nt_en b i t ( b i t 5 of contr ol r eg i ster 1, see
Tab l e 7) enab l es and d i sab l es the i nter r up t ci r cui tr y of O E/INT. The i r q _m od e b i t ( b i t 1 of
sp eci al - functi on r eg i ster 1, see Tab l e 14) p r og r am s the outp ut confi g ur ati on of INT and O E/INT
as op en- d r ai n or p ush- p ul l .
13 A3 RCV
D+ and D- Differential Receiver Output. In receive mode (see Table 4), when D+ is high and
D- is low, RCV is high. In receive mode, when D+ is low and D- is high, RCV is low. RCV is
low in suspend mode.
14 B3 SPD
Speed-Selector Input. Connect SPD to GND to select the low-speed data rate (1.5Mbps).
Connect SPD to V
L
to select the full-speed data rate (12Mbps). Disable the SPD input by
writing a 1 to spd_susp_ctl (bit 1 in special-function register 1, see Table 14). The speed bit
(bit 0 of control register 1, see Table 7) determines the maximum data rate of the MAX3301E
when the SPD input is disabled.
15 A4 V
L
System-Side Logic-Supply Input. Connect to the system’s logic-level power supply, +1.65V
to +3.6V. This sets the maximum output levels of the logic outputs and the input thresholds of
the logic inputs. Bypass to GND with a 0.1µF capacitor.
16 A5 SUS
Active-High Suspend Input. Drive SUS low for normal USB operation. Drive SUS high to
enable suspend mode. RCV asserts low in suspend mode. Disable the SUS input by writing
a 1 to spd_susp_ctl (bit 1 in special-function register 1, see Table 14). The suspend bit (bit 1
of control register 1, see Table 7) determines the operating mode of the MAX3301E when the
SUS input is disabled.
18 B4 INT
Active-Low Interrupt Source. Program the INT output as push-pull or open-drain with the
irq_mode bit (bit 1 of special-function register 2, see Table 15).
19 B5 RESET Active-Low Reset Input. Drive RESET low to asynchronously reset the MAX3301E.