MAX1672
Step-Up/Down DC-DC Converter
in QSOP Package
_______________________________________________________________________________________ 3
ELECTRICAL CHARACTERISTICS (continued)
(V
PS
= 6V, C
REF
= 0.1µF, C
OUT
= 4.7µF, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at T
A
= +25°C.) (Note 1)
Note 1: Specifications to -40°C are guaranteed by design.
ONA, ONB, 3/5; ILIM
T
A
= 0°C to +85°C
V
PGO
= 11V
I
PGO
= 2mA, V
PGI
= 1.2V
CONDITIONS
mV30Hysteresis
°C20
°C150Thermal Shutdown Threshold
Thermal Shutdown Hysteresis
V0.4Input Low Voltage
1.21 1.29
µA0.1 1
PGO Output Leakage
V0.1 0.4
PGO Output Low Voltage
UNITSMIN TYP MAXPARAMETER
ONA, ONB, 3/5; ILIM
V1.6Input High Voltage
__________________________________________Typical Operating Characteristics
(T
A
= +25°C, unless otherwise noted.)
Komentarze do niniejszej Instrukcji