and 100µA, the change in the measured voltage due to
series resistance is:
Since 1°C corresponds to 198.6µV, series resistance
contributes a temperature offset of:
Assume that the sensing diode being measured has a
series resistance of 3Ω. The series resistance con-
tributes a temperature offset of:
The effects of the ideality factor and series resistance
are additive. If the diode has an ideality factor of 1.002
and series resistance of 3Ω, the total offset can be cal-
culated by adding error due to series resistance with
error due to ideality factor:
1.36°C - 2.13°C = -0.77°C
for a diode temperature of +85°C.
MAX6695/MAX6696
Dual Remote/Local Temperature Sensors with
SMBus Serial Interface
_______________________________________________________________________________________ 7