ATF1502AS(L)
0995J–PLD–09/02
Notes: 1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. I
CC3
refers to the current in the reduced-power mode when macrocell reduced-power is turned on.
DC and AC Operating Conditions
Commercial Industrial
Operating Temperature (Ambient) 0°C-70°C-40°C-85°C
V
CC
(5V) Power Supply 5V ±5% 5V ± 10%
DC Characteristics
Symbol Parameter Condition Min Typ Max Units
I
IL
Input or I/O Low
Leakage Current
V
IN
=V
CC
-2 -10 µA
I
IH
Input or I/O High
Leakage Current
210
I
OZ
Tri-state Output
Off-state Current
V
O
=V
CC
or GND -40 40 µA
I
CC1
Power Supply Current, Standby V
CC
=Max
V
IN
=0,V
CC
Std Mode Com. 60 mA
Ind. 75 mA
“L” Mode Com. 10 µA
Ind. 10 µA
I
CC2
Power Supply Current,
Power-down Mode
V
CC
=Max
V
IN
=0,V
CC
“PD” Mode 1 5 mA
I
CC3
(2)
Reduced-power Mode
Supply Current, Standby
V
CC
=Max
V
IN
=0,V
CC
Std Mode Com. 35 mA
Ind. 40 mA
V
IL
Input Low Voltage -0.3 0.8 V
V
IH
Input High Voltage 2.0 V
CCIO
+0.3 V
V
OL
Output Low Voltage (TTL) V
IN
=V
IH
or V
IL
V
CC
=MIN,I
OL
=12mA
Com. 3.0 0.45 V
Ind. 0.45
Output Low Voltage (CMOS) V
IN
=V
IH
or V
IL
V
CC
=MIN,I
OL
=0.1mA
Com. 0.2 V
Ind. 0.2 V
V
OH
Output High Voltage (TTL) V
IN
=V
IH
or V
IL
V
CC
=MIN,I
OH
=-4.0mA
2.4 V