Functional Description (Continued)
Register
Address
Read/
Write
Register
Name
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
(LSB)
Default
Value
Lock?
6Fh R/W XOR Test Tree Enable RES RES RES RES RES RES RES XEN 00h U
74h R/W Tach Monitor Mode RES RES T3/4-1 T3/4-0 T2-1 T2-0 T1-1 T1-0 00h
75h R/W Fan Spin-up Mode RES RES RES RES RES PWM3
SU
PWM2
SU
PWM1
SU
7h U
Note: Reserved bits will always return 0 when read.
4.1 Register 20-24h: Voltage Reading
Register
Address
Read/
Write
Register
Name
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
(LSB)
Default
Value
20h R 2.5V 7 6543210 N/A
21h R V
CCP
7 6543210 N/A
22h R 3.3V 7 6543210 N/A
23h R 5V 7 6543210 N/A
24h R 12V 7 6543210 N/A
The Register Names difine the typical input voltage at which the reading is
3
4
full scale or C0h.
The Voltage Reading registers are updated automatically by the LM85 at a minimum frequency of 4 Hz. These registers are read
only a write to these registers has no effect.
4.2 Register 25-27h: Temperature Reading
Register
Address
Read/
Write
Register
Name
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
(LSB)
Default
Value
25h R Processor (Zone1) Temp 7 6543210 N/A
26h R Internal (Zone2) Temp 7 6543210 N/A
27h R Remote (Zone3) Temp 7 6543210 N/A
The Temperature Reading registers reflect the current temperatures of the internal and remote diodes. Processor (Zone1) Temp
register reports the temperature measured by the thermal diode connected to the Remote1− and Remote1+ pins, Remote
(Zone3) Temp register reports the temperature measured by the thermal diode connected to the the Remote2− and Remote2+
pins, and the Internal (Zone2) Temp register reports the temperature measured by the internal (junction) temperature sensor.
Temperatures are represented as 8 bit, 2’s complement, signed numbers, in Celsius, as shown below in Table 1. The Temperature
Reading register will return a value of 80h if the remote diode pins are not used by the board designer or are not functioning
properly. This reading will cause the zone limit bit(s) (bits 6 and 4) in the Interrupt Status Register (41h) and the remote diode fault
status bit(s) (bit 6 or 7) in the Interrupt Status Register 2 (42h) to be set. The Temperature Reading registers are updated
automatically by the LM85 at a minimum frequency of 4 Hz. These registers are read only a write to these registers has no
effect.
TABLE 1. Temperature vs Register Reading
Temperature Reading (Dec) Reading (Hex)
−127˚C −127 81h
.
.
.
.
.
.
.
.
.
−50˚C −50 CEh
.
.
.
.
.
.
.
.
.
0˚C 0 00h
.
.
.
.
.
.
.
.
.
127˚C 127 7Fh
LM85
www.national.com 10