Rainbow-electronics FARGO MAESTRO 100 (with TCP_IP) Instrukcja Użytkownika Strona 142

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 787
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 141
Serial Port Commands
Fixed DTE Rate +IPR
©Restricted
Page: 136 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 1 August 23, 2007
8.2.3 Parameters and Defined Values
<rate>: baud rates that can be used by the DCE
0 enables autobauding
300
600
1200
2400
4800
9600
19200
38400
57600
115200 default value
230400
460800
921600
8.2.4 Parameter Storage
The <rate> parameter is stored in EEPROM using AT&W command. The default value
can be restored using AT&F.
8.2.5 Examples
Command Responses
AT+IPR?
+IPR: 9600
OK
Note: Current rate is 9600 bps
AT+IPR=?
+IPR:
(1200,2400,4800,9600,19200,38400,5760
0,115200,230400,460800,921600),(0,300
,600,1200,2400,4800,9600,19200,38400,
57600,115200,230400,460800,921600)
OK
Note: Possible values, according to V25 ter
recommendation: the first set of values indicates the range
of auto-detectable baud rates .The second set of values
indicates the baud rates supported by the DCE.
Przeglądanie stron 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 786 787

Komentarze do niniejszej Instrukcji

Brak uwag