Rainbow-electronics FARGO MAESTRO 100 (with TCP_IP) Instrukcja Użytkownika Strona 179

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 787
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 178
Security Commands
Change Password +CPWD
©Restricted
Page: 173 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001 VOLUME 1 August 23, 2007
9.4.3 Parameters and Defined Values
<fac>: facility P2 SIM P2
"PS" SIM lock facility with a 8 digits password
"SC" PIN code 1/CHV1
"AO" BAOC (Barr All Outgoing Calls)
"OI" BOIC (Barr Outgoing International Calls)
"OX" BOIC-exHC (Barr Outgoing International Calls except to Home
Country)
"AI" BAIC (Barr All Incoming Calls)
"IR" BIC-Roam (Barr Inc. When Roaming outside Home Country)
"AB" All Barring services
"AG" All out Going barring services
"AC" All inComing barring services
"P2" PIN code 2/CHV2
"FD" SIM Fixed Dialing Numbers (FDN) memory feature (PIN2 is
required as <password>)
"PN" Network lock with a 8 digits password (NCK)
"PU" Network Subset lock with a 8 digits password (NSCK)
"PP" Service Provider lock with a 8 digits password (SPCK).
"PC" Corporate lock with a 8 digits password (CCK)
<oldpwd>: on 4 or up to 8 or 16 digits according to the facility
<newpwd>: new password specified for the facility
string type [….]
<pwdlength>: maximum length of the password for the facility
range: 4-16
9.4.4 Parameter Storage
None.
Przeglądanie stron 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 786 787

Komentarze do niniejszej Instrukcji

Brak uwag