42
8266A-MCU Wireless-12/09
9.4.1.4.5 State Transition Timing Summary
The transition numbers correspond to
Table 9-3 below. See measurement setup in
"Basic Application Schematic" on page 493.
Table 9-3. Radio Transceiver State Transition Timing
No Symbol
Transition Time [µs], (typ) Comments
1 t
TR2
SLEEP TRX_OFF 240
Depends on crystal oscillator setup (CL = 10 pf)
TRX_OFF state indicated by TRX24_AWAKE interrupt
2 t
TR3
TRX_OFF SLEEP 35 · 1 / f
CLKM
For f
CLKM
> 250 kHz
3 t
TR4
TRX_OFF PLL_ON 110 Depends on external capacitor at AVDD (1 µF nom)
4 t
TR5
PLL_ON TRX_OFF 1
5 t
TR6
TRX_OFF RX_ON 110 Depends on external capacitor at AVDD (1 µF nom)
6 t
TR7
RX_ON TRX_OFF 1
7 t
TR8
PLL_ON RX_ON 1
8 t
TR9
RX_ON PLL_ON 1 Transition time is also valid for TX_ARET_ON, RX_AACK_ON
9 t
TR10
PLL_ON BUSY_TX 16
When setting bit SLPTR or TRX_CMD = TX_START, the first
symbol transmission is delayed by 16 µs (PLL settling and
PA ramp up).
10 t
TR11
BUSY_TX PLL_ON 32 PLL settling time from TX_BUSY to PLL_ON state
11 t
TR12
All modes TRX_OFF 1
Using TRX_CMD = FORCE_TRX_OFF (see register
TRX_STATE),
Not valid for SLEEP state
12 t
TR13
RESET TRX_OFF 37 Not valid for SLEEP state
13 t
TR14
Various
states
PLL_ON 1
Using TRX_CMD = FORCE_PLL_ON (see register
TRX_STATE),
Not valid for SLEEP, RESET and TRX_OFF
The state transition timing is calculated based on the timing of the individual blocks
shown in Table 9-8 on page 51. The worst case values include maximum operating
temperature, minimum supply voltage, and device parameter variations.
Table 9-8. Analog Block Initialization and Settling Time
No Symbol
Block Time [µs], (typ) Time [µs], (max)
Comments
15 t
TR15
XOSC 215 1000
Leaving SLEEP state, depends on crystal Q factor and load
capacitor
16 t
TR16
FTN 25 FTN tuning time, fixed
17 t
TR17
DVREG 60 1000
Depends on external bypass capacitor at DVDD
(CB3 = 1 µF nom., 10 µF worst case), depends on V
DEVDD
18 t
TR18
AVREG 60 1000
Depends on external bypass capacitor at AVDD
(CB1 = 1 µF nom., 10 µF worst case) , depends on V
EVDD
19 t
TR19
PLL, initial 110 155
PLL settling time TRX_OFF PLL_ON, including 60 µs
AVREG settling time
20 t
TR20
PLL, settling 11 24 Settling time between channel switch
21 t
TR21
PLL, CF cal 35
PLL center frequency calibration, refer to "Calibration
Loops" on page 83
22 t
TR22
PLL, DCU cal 6
PLL DCU calibration, refer to "Calibration Loops" on
page 83
23 t
TR23
PLL, RX TX
16 Maximum PLL settling time RX TX